KGE12E

KGE12E
Product Code: KGE12E
Availability: In Stock
Enquire Now

Product Description

* Easier and more convenient electric starter

* New AVR(Automatic Voltage Regulator)

  stablizes the output power

* Low oil level alarming system will automatically

  stop the generator when lube oil is less than the set value

* A traditional open frame generator with a rugged and durable frame

Model KGE12E
Rated frequency (Hz) 50 60
Rated output (kVA) 8.5 9.5
Max. output (kVA) 9.5 10.5
Rated Voltage (V) 115/230 120/240
Rated current (A) 73.8/36.9 79.2/39.6
Rated rotation speed (r/min) 3000 3600
Phase NO. Single phase
Power factor (Cos Φ) 1.0
Insulation Grade B
Pole number 2
Excitation mode Self-excitation & constant voltage (AVR)
Panel Type General Panel
Voltage (V) 115/230 120/240
Receptacle Two receptacles
Connection pole With
DC12V output Without
Overall dimension(L×W×H)(mm) 910X600X760 910X600X620(without wheels)
Dry weight(kg) 161
Working assorting weight (Kg) 175  182
Noise level(7m)dB(A) 77
Structure type Open frame
Engine Model KG690
Engine Type Two-cylinder, air-cooled, four-stroke, V-twin, four-stroke,OHV
Cylinder NO.-bore×stroke (mm) 2-78×72
Displacement (ml) 688
Rated power [KW/(r/min)] 12.0/3000 14.0/3600
Compression ratio 8.5:1
Rated rotation speed (r/min) 3000 3600
Combustion system T.C.I
Cooling system Air cooled
Lubrication system Pressure splash
Starting system Electric starter
Fuel type Automatic unleaded gasoline
Lube oil brand CD grade or SAE10W-30,15W-40
Capacity of cooling water (L) Without
Lube capacity (L) 1.3
Starting motor capacity (V-kW) 12V 1.4kW
Charging generator capacity (V-A) 12V 8A
Battery capacity (V-Ah) 12V 36Ah
Fuel consumption (g/kW.h) ≤370
Fuel tank capacity (L) 25
Continuous running time (hr) 5

 

Digital Control Panel

The new gasoline genset model is equipped with a digital control system and remote control. Some control units of the generator sets are featured by multi function displays.

Real-Time Data Display

A monitor on the panel will display the real-time working data of the generator set. Output voltage, frequency, running time, and battery voltage as well as  generator fault information are displayed on the panel.

Low Oil Pressure Alarm System

Before the lube oil level drops to the critical level, the generator set will stop automatically. The set can only be restarted after the lube oil is refilled to the proper level.

New AVR  

The AVR (Automatic Voltage Regulator) provides not only a smooth output with all voltage ranges but also overload protection, protecting the generator from damages.

Electric Starter

A convenient electric starter gets the new gasoline generators up and running effortlessly and quickly.